Most Popular Frequent Questions
Server cabinets have specific requirements in terms of depth, height and load-bearing capacity. Available heights include 2.2 m, 2.0 m, 1.8 m, 1.6 m, 1.4 m, 1.2 m and 1 m; widths are available in three options: 800 mm, 700 mm and 600 mm; depths come in three specifications: 800 mm, 900 mm and 1000 mm.
Optional accessories include fixed mounting trays, sliding keyboard trays, power supply brackets, foot cups, ground anchor bolts, cable management rings, cable management racks, L-brackets and cross expansion beams. The main frame, front door and rear door can be quickly disassembled and assembled from the left and right sides.
Fixed Tray
Used for installing various equipment with flexible dimensional adaptability and wide application scenarios, including standard 19-inch trays and non-standard fixed trays. Standard fixed trays are available in depths of 440 mm, 480 mm, 580 mm and 620 mm, with a rated load capacity of no more than 50 KG.
Sliding Tray
Designed for mounting keyboards and other equipment; it can be freely pulled out and pushed back, compatible with all standard 19-inch cabinets. Standard sliding trays are offered in depths of 400 mm and 480 mm, with a rated load capacity of no less than 20 KG.
Power Distribution Unit
Optional power sockets compatible with all standard power plugs, fitted with a 19-inch mounting frame for flexible installation methods; 6-port configuration.
Parameters: AC 220 V, 10 A.
Cable Management Rack
Standard 19-inch cable management rack compatible with all TOPER series cabinets. It delivers optimal performance when paired with 12-port, 24-port and 48-port patch panels.
Cable Management Ring
Dedicated cable routing fitting for TOPER 1800 series and TOPER Server series cabinets. It features convenient installation and removal, with freely adjustable quantity and mounting positions.
L-Bracket
Matched with cabinets to install 19-inch standard equipment, especially heavy rack-mounted servers and other large-weight 19-inch devices.
Blank Panel
Covers vacant mounting positions inside 19-inch standard cabinets, available in multiple unit sizes such as 1U and 2U; 1U and 2U are the mainstream specifications.
Expansion Cross Beam
Exclusive to TOPER 1800 series and TOPER Server series cabinets for expanding internal installation space. Easy to assemble and disassemble, it supports mounting for cable management racks and power distribution units with diverse flexible layouts.
Mounting Nut (Cage Nut)
Applicable to all TOPER series cabinets for installing nearly all internal cabinet accessories.
Keyboard Tray
Holds standard computer keyboards compatible with mainstream keyboard models on the market; rotatable by 90 degrees. It must be installed together with a sliding tray.
Variable-Speed Fan Unit
Mounted on the cabinet top; fan speed can be adjusted according to ambient and equipment temperature to effectively reduce noise inside the machine room.
Speed control mode: manual stepless speed regulation.
Rack-Mounted Fan Unit
1U in height, installable at any height inside a 19-inch standard cabinet, deployed flexibly based on internal heat sources.
Full Mesh Front Door
The entire front door is covered with Φ3 round holes to enhance heat dissipation and electromagnetic shielding performance.
Compatible cabinet heights: 2.0 m, 1.8 m, 1.6 m.
Network cabinets, a subset of server cabinets, are assembled to mount panels, plug-ins, junction boxes, electronic components, mechanical parts and assemblies into an integrated enclosure. Widely applied in cabling engineering, they house routers, switches, monitors and patch panels. In general, network cabinets have a depth ≤ 800 mm, while server cabinets feature a depth ≥ 800 mm.
Network cabinets are engineered for convenient production, assembly, commissioning and packaging & transportation. Server cabinets comply with standardization, modularization and serialization requirements. All cabinets boast an elegant appearance, practical structure and harmonious color matching.
Optional accessories include fixed mounting trays, dedicated sliding trays, power brackets, foot casters, ground anchor bolts, cable management rings, cable management racks, L-brackets and extension cross beams. The main frame, front door and rear door can be quickly assembled and disassembled from the left and right sides.
Fixed Mounting Tray
It is used to install various types of equipment with diverse sizes and wide applicability, including standard 19-inch trays and non-standard fixed trays. Standard fixed trays are available in depths of 440 mm, 480 mm, 580 mm and 620 mm, with a load capacity of no less than 50 KG.
Sliding Tray
Designed for mounting keyboard trays and other equipment; it can be smoothly pulled out and pushed back. The 19-inch sliding tray fits all standard 19-inch cabinets. Standard sliding trays come in depths of 400 mm and 480 mm, supporting a load of no less than 20 KG.
Power Distribution Unit (PDU)
Optional power sockets compatible with all standard power plugs, fitted with a 19-inch mounting frame for flexible installation. Configuration: 6 outlets.
Parameters: AC 220 V, 10 A.
Cable Management Rack
Standard 19-inch cable management rack compatible with all TOPER series cabinets. It works best when matched with 12-port, 24-port and 48-port patch panels.
Cable Management Ring
Exclusively designed for TOPER 1800 series and TOPER Server series cabinets. It allows easy installation and removal, and its quantity and mounting positions can be adjusted arbitrarily.
L-Bracket
Matched with cabinets to install 19-inch standard equipment, especially heavy-duty rack-mounted servers and other large-weight 19-inch devices.
Blank Panel
Used to block vacant mounting spaces inside 19-inch standard cabinets, available in specifications such as 1U, 2U, etc. 1U and 2U are the mainstream types.
Extension Cross Beam
Custom-made for TOPER 1800 series and TOPER Server series cabinets to expand internal installation space. Easy to assemble and take apart; it can also be used for mounting cable management racks and PDUs with flexible installation forms.
Mounting Nut (Cage Nut)
Applicable to all TOPER series cabinets for installing all internal devices and most cabinet accessories.
Keyboard Tray
For installing standard computer keyboards compatible with most mainstream keyboards on the market; rotatable by 90 degrees. It must be installed together with a sliding tray.
Variable-Speed Fan Unit
Installed on the top of the cabinet. Fan speed can be adjusted according to ambient and equipment temperature to effectively reduce noise in the computer room.
Speed control: manual stepless speed regulation.
Rack-Mounted Fan Unit
1U in height, mountable at any position inside a 19-inch standard cabinet and deployed flexibly according to internal heat sources.
Full Mesh Front Door
The entire front door is perforated with Φ3 round holes to improve heat dissipation and electromagnetic shielding performance.
Applicable cabinet heights: 2.0 m, 1.8 m, 1.6 m.
Network cabinets are a category of server cabinets. They are assembled to mount panels, plug-ins, junction boxes, electronic components and mechanical parts into an integrated enclosure. Widely adopted in cabling projects, they accommodate routers, switches, monitors, patch panels and other devices.
Generally speaking, network cabinets have a depth ≤ 800 mm, while server cabinets feature a depth ≥ 800 mm. Network cabinets are designed for convenient production, assembly, commissioning, packaging and transportation. Server cabinets comply with requirements of standardization, normalization and serialization. All cabinets feature attractive appearance, practical structure and coordinated color matching.
When it comes to surveillance poles, everyone is familiar with their functions. Widely deployed on urban roads, these poles help elevate the standard of civilized urban traffic and strengthen urban public security. Specific specifications and precautions must be followed during their application.
Surveillance poles are fabricated from high-quality steel plates. Their installation must guarantee structural safety, stability and excellent wind resistance. In numerous cities, improper installation has led to poles being uprooted during typhoons or heavy rainstorms when they cannot withstand severe weather impacts. Such failures pose threats to passing vehicles and pedestrians, and severely disrupt urban traffic safety. Designed to safeguard public travel and standardize traffic order, surveillance poles must be installed properly to eliminate unnecessary safety hazards.
Standard surveillance poles are manufactured with a height of 4–6 meters and a 1-meter horizontal arm. Unless special requirements apply, vertical steel bars for foundation embedding shall be set in C25 grade concrete, with steel bars complying with standard specifications and wind-resistance requirements. The concrete adopts Grade 425 ordinary Portland cement; the concrete mix proportion and cement dosage shall conform to relevant industry codes.
Reliable earthing is mandatory for surveillance poles: lead wires shall be buried underground, and threads on anchor bolt flanges of embedded parts shall be wrapped for protection against damage. Embedded base components for vertical poles shall be positioned strictly per installation drawings to fix the outward direction of cantilever arms. As cameras are mounted at high elevations on the poles, direct lightning protection for equipment is essential, with a lightning rod fitted at the top of every surveillance pole.
When customers purchase cabinets, cabinet size is usually their primary consideration. When selecting dimensions, it is necessary to take not only the size of the equipment to be installed inside but also the space of the room intended for cabinet placement into account. Only comprehensive evaluation from multiple aspects can confirm the most suitable cabinet specification.
External factors should be fully considered not only when choosing cabinet sizes but also when purchasing other products. The standard cabinet width is 19 inches conventionally. Nevertheless, continuous iteration of IT equipment has made standard 19-inch cabinets unable to satisfy diversified demands. To tackle this problem, we provide customized cabinets tailored to individual client requirements. Cabinet manufacturers must focus on meticulous details to attract more customers, striving to fulfill practically any feasible customization demand.
To figure out the appropriate cabinet size, purchasers need to confirm the equipment to be installed and the operating environment requirements of such devices. Additional factors shall be evaluated, including whether the installed equipment will impair internal heat dissipation of the cabinet, as well as the maximum quantity of devices that can be accommodated within the selected cabinet.
A cabinet of any size can be regarded as a qualified option as long as it meets expected application performance. The core goal for buyers is to select a rational cabinet size and realize maximum space utilization.
Monitoring poles are column brackets for installing outdoor surveillance cameras. Road monitoring poles are generally manufactured with a height of 6 meters and a crossarm length of 1 meter. Unless otherwise specified, the embedded parts of all monitoring poles shall be cast with C25 concrete, and the matching steel bars shall comply with national standards and wind resistance requirements. Grade 42.5 ordinary Portland cement shall be adopted, and the concrete mix proportion and minimum cement dosage shall conform to the provisions of GBJ204-83.Manufacturers of monitoring poles shall implement reliable earthing construction with additional earthing leads buried underground (it is recommended not to conduct current through the pole body), and the earthing resistance shall be less than 4 ohms.